OTHER PRODUCTS
What are other products?
In addition to the angle measurement of the autocollimator method using a laser, we will introduce products such as measuring instruments that enable simultaneous measurement of displacement, light sources for laser solder, and wavefront aberration measuring devices for lenses.
Multi-axis measurement (6 axes)
High-speed 6D sensors
- MS-2000
This device is ideal for evaluation and inspection of camera module actuators with sensor shifting image stabilization functions mounted on smartphones, etc.
By using a special dedicated target, six items of tilt (θX, θY), displacement (Z), position (X, Y), and rotation (θ) of the object can be measured simultaneously with high accuracy.
Main specifications
Measurement range
Tilt (θX-θY): φ2deg
Displacement (Z): ±1mm
Position (X-Y): ±0.5mm
Rotation (θ): ±90min
Working distance: 90±0.5mm
Multi-axis measurement (5 axes)
High-speed 5D sensors
- MF-5550
This device is ideal for evaluation and inspection of camera module actuators with lens shifting image stabilization (OIS) mounted on smartphones, etc.
By using a dedicated target, five items of tilt (θX, θY), displacement (Z), and position (X, Y) of the object can be measured at high speed with high accuracy at the same time.
Main specifications
Measurement range
Tilt (θX-θY): φ2deg
Displacement (Z): ±1mm
Position (X-Y): ±0.5mm
Working distance: 80±0.5mm
Sampling: 10kHz
Multi-axis measurement (3 axes)
Displacement tilt sensor
- VH-1100 / VH-3100
It can be used to measure and evaluate VCM autofocus (AF) actuators mounted on smartphones, etc.
By using a mirror target, it is possible to measure the displacement (Z) and tilt (θX-θY) at the same time.
The measurement data is output in analog (±5V), allowing sampling at 10 kHz.
VH-1100
Measurement range tilt (θX-θY): φ2deg
Displacement (Z): ±1.5mm
Working distance: 60±0.5mm
Dimensions: W125×D150×H56mm
VH-3100
Measurement range tilt (θX-θY): φ4deg
Displacement (Z): ±2mm
Working distance: 80±0.5mm
Dimensions: W140×D150×H56mm
Common specifications
Sampling: 10kHz
Wide-angle displacement tilt sensor
- WH-2100
It can be used to measure and evaluate VCM autofocus (AF) actuators mounted on smartphones, etc.
By using a dedicated target, it is possible to measure the displacement (Z) and tilt (θX-θY) at the same time.
The measurement data is output in analog (±5V), allowing sampling at 10 kHz.
Measurement range tilt (θX-θY): φ10deg
Displacement (Z): ±5mm
Working distance: 71±0.5mm
Dimensions: W185×D230×H56mm
Sampling: 10kHz
Lens measurement (wavefront aberration measurement)
Full-field wavefront aberration measuring device
- AW-1000
It is a device that can measure wavefront aberrations on and off the optical axis of the lens fully automatically.
Main measurement items
Wavefront (2D, 3D)
Point image distribution
Zernike polynomials
MTF (1, all frequencies, 2, all rotation directions, 3, through focus)